關鍵字查詢 | 類別:期刊論文 | | 關鍵字:Modified correction-factor analysis for mass transfer in double-pass rectangular membrane modules

[第一頁][上頁]1[次頁][最末頁]目前在第 1 頁 / 共有 03 筆查詢結果
序號 學年期 教師動態
1 101/2 秘書處 何啟東 教授 期刊論文 發佈 Modified correction-factor analysis for mass transfer in double-pass rectangular membrane modules , [101-2] :Modified correction-factor analysis for mass transfer in double-pass rectangular membrane modules期刊論文Modified correction-factor analysis for mass transfer in double-pass rectangular membrane modulesH. M. Yeh; C. D. Ho; C. S. Chiang; C. H. ChenThe Canadian Journal Chemical Engineering 91(3), pp.499-505en_US國外SCI;EI;否USA
2 101/2 化材系 葉和明 教授 期刊論文 發佈 Modified correction-factor analysis for mass transfer in double-pass rectangular membrane modules , [101-2] :Modified correction-factor analysis for mass transfer in double-pass rectangular membrane modules期刊論文Modified correction-factor analysis for mass transfer in double-pass rectangular membrane modulesYeh, Ho-ming; Ho, Chii-Dong; Chiang, Chiung-Sheng; Chen, C. H.淡江大學化學工程與材料工程學系Hoboken: Wiley-Blackwell Publishing, Inc.Canadian Journal of Chemical Engineering 91(3), pp. 499-505Mass transfer in mass exchangers, such as membrane extractors and dialysers, can be analogous to heat transfer in heat exchangers with correction-factor analysis. In present study, the expressions of mass-transfer rate and correction-factor charts for mass transfer in parallel-flow double-pass rectangular membrane modules were modified by the modified correction-factor analysis, instead of the conventional correction-factor analysis. They are explicit, instead of implicit in the conventional correction-factor analysis. The results can be readily calculated without using trial-and-error method. Experimental results con
3 101/2 化材系 何啟東 教授 期刊論文 發佈 Modified correction-factor analysis for mass transfer in double-pass rectangular membrane modules , [101-2] :Modified correction-factor analysis for mass transfer in double-pass rectangular membrane modules期刊論文Modified correction-factor analysis for mass transfer in double-pass rectangular membrane modulesYeh, Ho-ming; Ho, Chii-Dong; Chiang, Chiung-Sheng; Chen, C. H.淡江大學化學工程與材料工程學系Hoboken: Wiley-Blackwell Publishing, Inc.Canadian Journal of Chemical Engineering 91(3), pp. 499-505Mass transfer in mass exchangers, such as membrane extractors and dialysers, can be analogous to heat transfer in heat exchangers with correction-factor analysis. In present study, the expressions of mass-transfer rate and correction-factor charts for mass transfer in parallel-flow double-pass rectangular membrane modules were modified by the modified correction-factor analysis, instead of the conventional correction-factor analysis. They are explicit, instead of implicit in the conventional correction-factor analysis. The results can be readily calculated without using trial-and-error method. Experimental results con
[第一頁][上頁]1[次頁][最末頁]目前在第 1 頁 / 共有 03 筆查詢結果